Introduction:
The active energy meter EL -EPM01 was designed for monitoring and measuring electrical loads. It is presented in the form of an effective solution in determining costs.
The measuring range of the Energy Meter extends from 5W to 3680W (maximum current of 16A). If the values fall below or exceed these limit values, accurate measurements can no longer be performed. Also, the device can be overloaded and, as a result, destroyed.
Features:
Current time (24 hours), week, electrical load and consumption cost
Total time, total energy used as well as increased energy costs.
Total recording time, total time and percentage
Dual energy consumption program
Before use:
The active energy meter is only suitable for operation with 230V AC sources. It can only be connected to 230V AC 50/60Hz power sources.
The operation of the Energy Meter is only allowed in closed spaces and in dry environments. Do not use the Energy Meter in open spaces.
Always read the identification labels of the connected devices to check if their specifications correspond to those of the Energy Meter.
Connection:
After connecting the Energy Meter to a socket or a power source, the capacitors within the device will charge. After 15 minutes, the capacitors will have enough energy to turn on the LCD display. At this moment, the current time and energy consumption can be adjusted.
Note: the internal Li-ion battery used to support the LCD display needs at least 12 hours to fully charge.
Technical data
Operating voltage 230V AC/50/60Hz, alternative voltage; (AC)
Maximum connected current 3680w
Maximum current 16A
Rechargeable battery 2.6V, 40mAH, 12 H, 4mA
Power absorbed/power consumed via a connection plug/ protected outlet
Working temperature +10°C to +40°C
Energy display 0kwh -999.9 kwh
Maximum recording time 9999 hours
Working temperature +5 °C to +40°C
Working humidity 80% below 31°C, from 31°C to 40°C this figure decreases linearly to 50%
IP20 degree of protection
Pollution degree 2
Notes: Do not use two Energy Meters at the same time